Features:
※ signal input: single-ended, pulse / direction
※ subdivision optional: 1/2/4/8/16/32 subdivision
※ Output current: 0.25A-2.00A
※ Input voltage: 9-32VDC
※ automatic quiescent current halved
※ Can drive 4, 6, 8 line two-phase, four-phase stepper motor
Optocoupler isolation signal input, anti-interference ability
※ With overheating, over-current, under-voltage lock, input voltage anti-reverse protection and other functions
※ small size, easy to install
※ External signal 3.3-24V common, no series resistance
Electrical environment:
cooling method
Natural cooling or forced air cooling.
occasion
Do not place it near other hot equipment. Avoid dust, oil, corrosive gas, excessive humidity and strong earthquakes. Do not use combustible gas or conductive dust.
humidity
40-90%RH
shock
10-55Hz/0.15mm
Save the temperature
-20-65℃
weight
0.25KG
Subdivision settings:
Set the subdivision (1 axis and 2 axes) with 1, 2, and 3 DIP switches as follows:
Subdivision
S1
S2
S3
1
ON
ON
ON
2
OFF
ON
ON
4
ON
OFF
ON
8
OFF
OFF
ON
16
ON
ON
OFF
32
OFF
ON
OFF
32
ON
OFF
OFF
32
OFF
OFF
OFF
Current setting:
Use 4, 5, and 6 DIP switches to set the current (1 axis and 2 axes are the same) as the following table:
Current
S4
S5
S6
0.25
ON
ON
ON
0.55
ON
ON
OFF
0.75
ON
OFF
ON
1.00
ON
OFF
OFF
1.45
OFF
ON
ON
1.60
OFF
ON
OFF
1.75
OFF
OFF
ON
2.00
OFF
OFF
OFF
Wiring diagram:
Product Size:
Product physical map: