1. [Precision Machined MEASUREMENT] Made of permalloy with double layer shielding technology for minimal external magnetic field interference, ensuring consistent and reliable results.
2. [PORTABLE DESIGN] Clamp-shaped for non-contact measurement without line disconnection, promoting safety and efficiency.
3. [VERSATILE CONNECTIONS] Compatible with various devices like phase analyzers, data loggers, and multimeters for diverse testing needs.
4. [WIDE APPLICATION] Ideal for AC leakage current, harmonic current, power factor, and more in industries like power, communication, and research.
5. [OUTPUT FLEXIBILITY] Supports multiple interfaces like BNC plug and banana plug, offering convenience and adaptability.
Spec:
item type: current transformer
Model:
Material: ABS+Permalloy
Uses: It is suitable for AC leakage current detection, and is widely used in electric power, communications, meteorology, railways, oil fields, construction, measurement, scientific research and teaching units, industrial and mining enterprises and other fields.
Range Resolution Accuracy Grade Phase Error Transformation Ratio
0.00mA~40A AC 0.01mA 0.5 ≤2° 800:01:00
Function It is suitable for Precision Machined detection of AC leakage current, high order harmonic current, phase, electric energy, power, power factor, etc.
Model
Measuring Range 0.00mA-40A AC
Resolution 0.01mA
Accuracy Class 0.5
Phase Error ≤2°
Transformation Ratio 800:01:00
Reference Load ≤120Ω
Jaw Size Approx. / 1.4x1.6in
Quality Approx. 190g / 6.7oz
Output Interface BNC Plug/4.0mm Double Banana Plug/3.5mm Audio Plug/Bare Wire Tap (Optional), Cable Length Approx. 1.5m / 4.9ft
Working Frequency 45Hz-100kHz
Dielectric Strength AC 3700V/Rms (Between Core And Shell)
Security Level CATⅢ600V
Output Method Inductive Current Output
Working Temperature and Humidity -15℃-50℃; Below 80%rh
How to Use:
1. Multimeter (MA Level Current File)
It can directly view the current value after the transformer transformation ratio, the standard configuration is 2500:1.
2. Oscilloscope
For the measurement of direct current or alternating current, the indirect method is generally used.
Specific Method: first transform the amount of current into a proportional voltage amount, and then observe with an oscilloscope
General Test Method: Connect a non inductive resistor with Precision Machined and small resistance in series in the circuit under test, and then measure the voltage with an oscilloscope to measure the effective value of the voltage at both ends of the resistor, and then calculate the measured current value , Its calculation formula is 1=U/R. In the formula, the measured current value A; the effective value V of the voltage at both ends of the series resistance; R the resistance value of the series connected non inductive resistance Ω.
3. Other Instruments
It can be combined with self developed instruments and meters, and can be used as a current probe.
Clamp the live wire or null wire alone to measure the current of the line. (Note that 1 stick must be stuck)
Clamp the live wire and null wire together to measure the single phase leakage current. (Note that 2 sticks need to be stuck)
Clamp the ground wire to measure the leakage current of the ground wire of the electrical equipment. (Note that 1 stick must be stuck)
PackageList:
1 x Current Transformer