Audio Transformers
Part number: RSO 825034
Description: RKT150VA2x1 15V/2x18.0V 2x4.17A
Safety isolation standard: EN 61558-2-6 1 VDE 0570
Power [VA]: 150
Input voltage [AC]: 2x 115 V +-10%
Output voltage [AC]: 2x 18.00 V
Output current [AC]: 2x4.17 A
Frequency [Hz]: 50/60
Dielectric strength PRI-SEC [AC]: 4400 V
Conversion efficiency [%]: 90
No-load power loss[W]:1.33
Maximum ambient temperature ta ["C]: 60
Heat resistance class: B (130"C)
Temperature switch: 120C (auto reset)
Primary connection method:
Primary 1, Primary 2
Parallel 115V=blue+monitor, brown+brown
Series 230V=brown+monitor
Secondary connection method:
Secondary 1, Secondary 2
Parallel 18.0V18.34A=black+purple, red+
Series 36.0V14.17A = red + purple
Lead wire: primary and secondary lead wire length 200mm, bushing installed at the end of the lead wire
Installation method: embedded mounting plate + 8.1mm through hole
Anti-shock level: prepared for class II
Protection class: IP 00
Recommended fuse value:
Primary: 2.50AT/1.25AT(115V1 230V)(IEC60127-2-5)
Secondary 1: 5.00AT (IEC60127-2-3)
Secondary 2: 5.00AT (IEC60127-2-3)
size:
Outer diameter: 115mm
Height: 47mm
Weight: about 1.85kg!