Note: When testing the machine, the output transformer must be connected to a horn or a resistor as a load. The no-load test can easily burn the transformer. This kind of burnt is not guaranteed by our shop.
Specifications
Transformer primary impedance 5K, secondary impedance 0-4-8
Core size: 22MM*44MM
Winding method: 3 clips 2 (primary divided into 3 sections, secondary divided into two sections)
Inductance: L >= 25H (Test frequency is 100HZ, Z11 piece)
Primary wire diameter: 0.15MM air gaps 0.08MM
Secondary wire diameter: 0.53MM two parallel
Core material: 0.35MM thick insulation annealing sheet, stack thickness 44MM.
Shielding method: painted iron side cover
Weight: 1.3KG
Volume: 68MM wide * 58MM high * 80MM thick, the center point of the mounting hole is: 80MM (horizontal installation)
68MM high*66MM wide*80MM thick, the center distances of the installation feet is: 60MM*44MM (vertical installation)
Bandwidth: 30HZ-20KHZ
[Z11 piece vertical with side cover installation, lead out]
Horizontal iron bridge installation with side cover
Vertical purple gold spray hood installation
==========
High-concerned chemical : None
Coil Number : Autotransformer
Phase : SINGLE
Origin : Mainland China
Use : AUDIO