Search

Home / GAVATKLKCP / Passive Components
-48%
RF Low Pass Filter LPF 30/100/200/500/800/1000/1200/1400/2000/2400Mhz Signal Radio Frequency LC(LPF 30Mhz) in Saudi Arabia

LPF 500Mhz

SAR 68
SAR 130

Brand
GAVATKLKCP
Weight
50 g
SizeLPF 500Mhz
1 +

Special Features

  • Compact Design:At just 54.5*13.5*8mm, these filters are space-efficient, making them ideal for compact electronic setups.
  • Low Standing Wave Ratio:Boasting a standing wave ratio of ≤1.5, these filters minimize signal distortion and maximize clarity.
  • Low Insertion Loss:With an insertion loss of ≤2.0dB at 30Mhz and ≤1.0dB at higher frequencies, these filters maintain signal integrity.
  • High Power Capacity:Capable of handling up to 8W of power, these filters ensure reliable performance under high input levels.
  • Wide Frequency Range:Covering 30Mhz to 2400Mhz, these filters provide versatile signal management for diverse radio applications.

Description

Application:
Harmonic rejection
transmitters/receivers
Anti-aliasing for A/D converter
30M Low pass filter:
Module parameters:
Operating frequency: DC-30MHz;
Insertion loss: 2.0dB@30MHz;
Input-output standing wave: 1.5;
Input and output impedance: 50 ohms;
Power capacity: 2W;
Out-of-band suppression: See test curve;
Input/output interface: SMA-M,SMA-F;
Module size: 54.5*13.5*8mm;
Note: Modules have no input or output;
100M low pass filter:
Module parameters:
Operating frequency: DC-100MHz;
Insertion loss: 1.3dB@30MHz;
Input-output standing wave: 1.5;
Input and output impedance: 50 ohms;
Power capacity: 2W;
Out-of-band suppression: See test curve;
Input/output interface: SMA-M,SMA-F;
Module size: 54.5*13.5*8mm;
Note: Modules have no input or output;
200M low-pass filter:
Module parameters:
Operating frequency: DC-200MHz;
Insertion loss: 1.0dB@30MHz;
Input-output standing wave: 1.5;
Input and output impedance: 50 ohms;
Power capacity: 2W;
Out-of-band suppression: See test curve;
Input/output interface: SMA-M,SMA-F;
Module size: 54.5*13.5*8mm;
Note: Modules have no input or output;
500M low pass filter:
Module parameters:
Operating frequency: DC-500MHz;
Insertion loss: 1.0dB@500MHz;
Input-output standing wave: 1.2;
Input and output impedance: 50 ohms;
Power capacity: 8W;
Out-of-band suppression: See test curve;
Input/output interface: SMA-M,SMA-F;
Module size: 35*8.5*8mm;
Note: The module has no input and output, and can be used in two cascades to improve out-of-band signal suppression;
800M low-pass filter:
Module parameters:
Operating frequency: DC-800MHz;
Insertion loss: 1.0dB@800MHz;
Input-output standing wave: 1.2;
Input and output impedance: 50 ohms;
Power capacity: 8W;
Out-of-band suppression: See test curve;
Input/output interface: SMA-M,SMA-F;
Module size: 35*8.5*8mm;
Note: The module has no input and output, and can be used in two cascades to improve out-of-band signal suppression;
1000M low-pass filter:
Module parameters:
Operating frequency: DC-1000MHz;
Insertion loss: 1.0dB@1000MHz;
Input-output standing wave: 1.3;
Input and output impedance: 50 ohms;
Power capacity: 10W;
Out-of-band suppression: See test curve;
Input/output interface: SMA-M,SMA-F;
Module size: 35*8.5*8mm;
Note: The module has no input and output, and can be used in two cascades to improve out-of-band signal suppression;
1200M low-pass filter:
Module parameters:
Operating frequency: DC-1200MHz;
Insertion loss: 1.0dB@1200MHz;
Input-output standing wave: 1.2;
Input and output impedance: 50 ohms;
Power capacity: 10W;
Out-of-band suppression: See test curve;
Input/output interface: SMA-M,SMA-F;
Module size: 35*8.5*8mm;
Note: The module has no input and output, and can be used in two cascades to improve out-of-band signal suppression;
1500M Low pass filter:
Module parameters:
Operating frequency: DC-1500MHz;
Insertion loss: 1.0dB@1500MHz;
Input-output standing wave: 1.2;
Input and output impedance: 50 ohms;
Power capacity: 10W;
Out-of-band suppression: See test curve;
Input/output interface: SMA-M,SMA-F;
Module size: 35*8.5*8mm;
Note: The module has no input and output, and can be used in two cascades to improve out-of-band signal suppression;
2000M low-pass filter:
Module parameters:
Operating frequency: DC-2000MHz;
Insertion loss: 1.5dB@2000MHz;
Input-output standing wave: 1.3;
Input and output impedance: 50 ohms;
Power capacity: 10W;
Out-of-band suppression: See test curve;
Input/output interface: SMA-M,SMA-F;
Module size: 35*8.5*8mm;
Note: The module has no input and output, and can be used in two cascades to improve out-of-band signal suppression;
2.4G low-pass filter:
Module parameters:
Operating frequency: DC-2400MHz;
Insertion loss: 1.7dB@2400MHz;
Input-output standing wave: 1.3;
Input and output impedance: 50 ohms;
Power capacity: 10W;
Out-of-band suppression: See test curve;
Input/output interface: SMA-M,SMA-F;
Module size: 35*8.5*8mm;
Note: The module has no input and output, and can be used in two cascades to improve out-of-band signal suppression;

Related Items


{"error":"Error","cart_limit":"You have too many items in your cart.","prod_limit":"You cannot add any more of this item"}