Search

Home / PULME / Controls & Indicators
Solid State Relay 100A Three Phases 90-480VAC Voltage SSR 3-32V DC Control AC (ZG33-3100B) in Saudi Arabia Solid State Relay 100A Three Phases 90-480VAC Voltage SSR 3-32V DC Control AC (ZG33-3100B) in Saudi Arabia Solid State Relay 100A Three Phases 90-480VAC Voltage SSR 3-32V DC Control AC (ZG33-3100B) in Saudi Arabia Solid State Relay 100A Three Phases 90-480VAC Voltage SSR 3-32V DC Control AC (ZG33-3100B) in Saudi Arabia Solid State Relay 100A Three Phases 90-480VAC Voltage SSR 3-32V DC Control AC (ZG33-3100B) in Saudi Arabia Solid State Relay 100A Three Phases 90-480VAC Voltage SSR 3-32V DC Control AC (ZG33-3100B) in Saudi Arabia

Solid State Relay 100A Three Phases 90-480VAC Voltage SSR 3-32V DC Control AC (ZG33-3100B)

SAR 329

Brand
PULME
Weight
450 g
1 +

Special Features

  • The input adjustment range is wide, the output adjustment precision is high, the three-phase symmetry is good, and the anti-interference ability is strong.
  • There is a phase loss protection function. When the module is out of phase due to three-phase electrical input or the voltage is unstable, the module will immediately turn off the three-phase output to avoid load damage, so as to avoid production loss.
  • The input control has a wider adjustment range, a finer signal resolution, and a higher output voltage regulation accuracy.
  • The product is also suitable for the speed regulation of small power three-phase torque motor, and the speed regulation of fans, pumps, etc., and can also be applied to the slow start of AC motors.

Description

Features:
1) Small volume and dimensions
2) Universal fit
3) Safety EGIS cover
4) Zero current turn-off
5) Input loop and output loop light isolated
6) LED indicator (function and alarm) Details:
Load Current 10A, 15A, 20A, 25A, 30A, 40A, 50A, 60A, 75A, 80A, 90A, 100A, 120A
Load Voltage 480VAC
Control Voltage 3-32VDC
Control Current 10-68mA
On Voltage 1.5VAC
Off-state Leakage Current 10mA
Time Off 10ms
Dielectric Strength 2500VAC
Insulation Resistance 100M /500VDC1
Ambient Temperature -25~+75º C-25~+75º C
Mountiong Methods Bolt
The work instructions LED
Weight 450g
Note:
1. Load current 10A, should install radiator, for current upwards 40A, should add fan for force cooling or water cooling.
2. When using inductive load, please add a varisor at the output side, the value is 1.6~1.9 mutiple of load voltage.
Product standard
ZG33- DA(Basis Type)
Load Current
10A,15A,20A,25A,30A,40A,50A, 60A,75A,80A,90A,100A,120A
Load Voltage
480VAC
Control Voltage
3-32VDC
Control Current
10-68mA
On Voltage
1.5VAC
Off-state Leakage Current
10mA
Time Off
10ms
Dielectric Strength
2500VAC
Insulation Resistance
100M/500VAC
Ambient Temperature
-25~+75
Mountiong Methods
Bolt
The work instructions
LED
Weight
450g