Search

Home / FEIYING / Electrical Testing
FEIYING Digital Tester Handheld Diode Triode Resistor Transistor Capacitor ESR Transistor Meter in Saudi Arabia FEIYING Digital Tester Handheld Diode Triode Resistor Transistor Capacitor ESR Transistor Meter in Saudi Arabia FEIYING Digital Tester Handheld Diode Triode Resistor Transistor Capacitor ESR Transistor Meter in Saudi Arabia FEIYING Digital Tester Handheld Diode Triode Resistor Transistor Capacitor ESR Transistor Meter in Saudi Arabia FEIYING Digital Tester Handheld Diode Triode Resistor Transistor Capacitor ESR Transistor Meter in Saudi Arabia FEIYING Digital Tester Handheld Diode Triode Resistor Transistor Capacitor ESR Transistor Meter in Saudi Arabia FEIYING Digital Tester Handheld Diode Triode Resistor Transistor Capacitor ESR Transistor Meter in Saudi Arabia

FEIYING Digital Tester Handheld Diode Triode Resistor Transistor Capacitor ESR Transistor Meter

Sorry, this product is not available

Brand
FEIYING

Special Features

  • Package included: 1 x Transistor Tester
  • Short circuit ports T1, T2, and T3 together and press the ""Start/Test"" button.
  • Small device placement area: Places small volume devices for easy search and measurement.
  • External probe: Supports multiple probes, such as capacitance test clips, crocodile clips, and multimeter probes.
  • Disconnect the connection, the program will continue calibration, and finally display ""Test End"" to complete the calibration.

Description

value increases, it becomes longer.

7. Small device placement area: Places small volume devices for easy search and measurement.

8. External probe: Supports multiple probes, such as capacitance test clips, crocodile clips, and multimeter probes.

9. The back of the instrument is equipped with a reference table for typical ESR values of electrolytic capacitors, which facilitates users to make preliminary judgments on the quality of the measured capacitors.

The ESR values of capacitors produced by different manufacturers may vary, and the data provided by the manufacturer shall prevail. This table is for reference only.

VI calibration

1. Short circuit ports T1, T2, and T3 together and press the ""Start/Test"" button.

2. The screen prompts ""Self test mode..?"", and within 2 seconds, press the ""Start/Test"" button to confirm entering calibration. Otherwise, it will

Enter normal transistor test mode.

3. The instrument starts automatic calibration until the prompt ""isolate Probes!"" is displayed. At this time, disconnect T1, T2, and T3.

4. Disconnect the connection, the program will continue calibration, and finally display ""Test End"" to complete the calibration.

Packaging: 175mm * 100mm * 60mm

Weight: 260g (excluding batteries and other accessories)