Search

Home / Generic / Semiconductor Products
MR9270S + HART 4-20MA Signal Generator Calibrate Current Voltage PT100 Thermocouple Pressure Transmitter Recorder Frequency in Saudi Arabia MR9270S + HART 4-20MA Signal Generator Calibrate Current Voltage PT100 Thermocouple Pressure Transmitter Recorder Frequency in Saudi Arabia MR9270S + HART 4-20MA Signal Generator Calibrate Current Voltage PT100 Thermocouple Pressure Transmitter Recorder Frequency in Saudi Arabia

MR9270S + HART 4-20MA Signal Generator Calibrate Current Voltage PT100 Thermocouple Pressure Transmitter Recorder Frequency

SAR 2,419

Brand
Generic
Weight
1.5 kg
1 +

Special Features

  • Simultaneously measure and output signals.
  • The current and voltage signals can be programmed for output, with two output modes.
  • The first mode: Set the starting point, ending point, and number of cycles to start working.
  • The second mode: advanced mode, where signal changes are all set by parameters.
  • Convert the input signal into an output signal, for example: convert the input frequency signal into a current signal, and convert the input range from 0-1000Hz to 4-20mA.

Description

Real time curve: The change trend of input and output signals can be displayed through a curve, the collection time of the curve can be set, and the curve can be automatically displayed within a certain time range of maximum and minimum values.

Conversion of engineering quantity display: The signal is displayed as a signal value or engineering quantity, and the signal value corresponds linearly to the engineering quantity. For example, a 4-20mA signal corresponds to 0-100, that is, 4mA corresponds to 0, 12mA corresponds to 50, and 20mA corresponds to 100. This range can be modified through parameters.

Modbus RTU remote control: It can communicate with configuration software or PLC through RS485 to achieve online setting of instrument output signals and monitoring of instrument input signals.

Modbus RTU master station: Conduct communication testing, parameter setting, parameter copying, online monitoring, and other operations on slave devices with RS485 MODBUS interface.

Modbus Rtu custom slave station: can simulate all types of variables of modbus devices for configuration software or PLC debugging

Instrument Toolset: As a functional extension of the instrument, such as a simple paperless recorder, PID controller, etc. Please pay attention to the product website for details, and this manual is not provided for description.

USB firmware upgrade: Upgrade new firmware to expand new features.

USB to Rs485: The instrument can be used as a USB to RS485 virtual serial port, and operating systems below WIN10 require the installation of drivers.

Parameter:
Built in 3.6V 2500mA polymer lithium battery; The standby time is about 20 hours; The usage time varies depending on the usage situation (20mA continuous output can reach 8-10 hours)
Working environment: 0 ° C-50 ° C.
Internal reverse and overcurrent protection; Protection voltage: 30V
Size: 97mm * 76mm * 33mm
Weight: 189 grams