Whatman 2108 SteriVENT PTFE 150 Venting Filter Membrane, 1.5" Sanitary Inlet and Outlet, 0.2 Micron in Saudi Arabia

Whatman 2107 SteriVENT PTFE 150 Venting Filter Membrane, 1/2" Stepped Barb Fitting, 0.2 Micron

SAR 917

Brand
Whatman
Category
Lab Filters
1 +

Special Features

  • Fittings: 1.5 inch sanitary
  • Filtration Area: 2000 sq cm; pore size: 0.2 µm
  • Hydrophobic PTFE membranes and polypropylene housings
  • Retain > 107 CFU/cm2 Brevundimonas diminuta per ASTM F838-83 standards
  • Applications include sterile venting (filling) of vessels and tanks, isolation (incubators, autoclaves, lyophilizers, EtO sterilizers, fermenters), and Electronics (gases)

Description

SteriVENT are integral filters for sterile venting of vessels and tanks. They are constructed from a single, standardized set of materials - PTFE membranes and polypropylene housings. Retain > 107 CFU/cm2 Brevundimonas diminuta per ASTM F838-83 standards. The membrane is made of hydrophobic 0.2 µm PTFE membrane. This filter is validated for 50 steam autoclave cycles; compatible with EtO. Pass USP Class VI biosafety tests for plastics. Manufactured in clean room facilities. Applications include venting (filling), isolation (incubators, autoclaves, lyophilizers, EtO sterilizers, fermenters), and Electronics (gases). Fittings: 1.5inch sanitary. Filtration Area: 2000 sq cm. Pore size: 0.2 µm. 1/Pack. Whatman #: 2108.