3PCS 12V-36V DC Voltage Protection Module XH-M609 Digital Low Voltage Protection Module in Saudi Arabia 3PCS 12V-36V DC Voltage Protection Module XH-M609 Digital Low Voltage Protection Module in Saudi Arabia 3PCS 12V-36V DC Voltage Protection Module XH-M609 Digital Low Voltage Protection Module in Saudi Arabia 3PCS 12V-36V DC Voltage Protection Module XH-M609 Digital Low Voltage Protection Module in Saudi Arabia 3PCS 12V-36V DC Voltage Protection Module XH-M609 Digital Low Voltage Protection Module in Saudi Arabia

3PCS 12V-36V DC Voltage Protection Module XH-M609 Digital Low Voltage Protection Module

SAR 59

Brand
Diitao
Weight
14 g
1 +

Special Features

  • 【Application】The voltage protection module can be used for DC12-36V lead acid battery and lithium ion battery.
  • 【Parameter】Board Size 57 X 42 X 19mm/2.24 X 1.65 X 0.75inch(LxWxH);Input Voltage Range DC12-36V;Control Accuracy 0.1V, Power Consumption <1.5W;Maximum Amperage before Breaker Trips: 20A.
  • 【Long Lifetime】When voltage reach the setting values, the module will disconnect load automatically and can avoid the battery from over discharging,which can help prolong the battery lifetime.
  • 【Protect Circuit】With accurate display function, when it is close to the minimum voltage, the module can open or close in time.
  • 【Package】3pcs DC 12V-36V voltage protection module. If you have any questions after purchase, feel free to tell us.

Description

【 Instruction 】
Press + to view the disconnect voltage.
Press - to view the difference.
Press the "+" key twice. When the decimal point flashes, press the "+" or "-" key to set the disconnect voltage.
Double press the "-" key, and when the decimal point flashes, press the "+" or "-" key to set the difference.
Long press the "+" key, and when the LED screen flashes, press the "+" or "-" key to calibrate the input voltage.
Hold down the - key, and then press + or - to set the delay value T.
When the output voltage reaches the reconnection value, the load is reconnected after a delay of T minutes.
The delay time ranges from 000 to 010 minutes and is displayed as 000 or 001 or 005 or 010. The decimal point is not displayed.

【 Example 】
Setting below 12.5V will stop, higher than 14V will start.
Set the protection value: Press the "+" key once to display the protection value. Double-click the "+" key and the decimal point flashes. Press "+" and "-" to change the value to 12.5.
Set the return difference: Press the "-" key once to display the return difference, double-click the "-" key, the decimal point flashes, press the "+" and "-" keys to change the value to 1.5.
If there is no operation in 3 seconds, the module will automatically save and exit the setting mode.