Multi-diameter compatibility: The applicable diameter range is 80 - 200mm. It can be used in conjunction with different specifications of range hoods and exhaust fans' air outlets.
Adjustable length: The pipe body can be axially stretched or compressed to meet the requirements of different distances for smoke exhaust connections, reducing the need for cutting and splicing processes.
Material composition: It is made of aluminum foil composite material, with embedded steel wire support structure. The tube body can maintain a stable shape within a certain temperature range.
Bendable feature: It has a certain degree of flexibility and can be moderately bent according to the installation path, making it suitable for connections at corners or offset positions.
Compression packaging: When delivered, it is in a compressed state. Once unfolded, it can be used immediately. It occupies less space during storage and transportation.
وصف
Length: 1.5m
Material: Aluminum
Temperature range: -30 ~ 100
Pressure: 2500 pa
Air: 30 m/s
Diameter: Approx. 80/100/120/150/160/170/180/200mm
is_customized : Yes
Shape : Rectangular
Ventilation Duct : Vents
Hand Tool Parts : Ventilator Pipe
PVC Aluminum Tube : Air Ventilation Pipe
Hose Flexible : Exhaust Duct
Air System Vent : Bathroom Accessories
Kitchen Accessories : Aluminum Foil Ducting
Dryer Vent Hose : ventilation exhaust pipe
Aluminum foil telescopic hose : exhaust hood special smoke pipe
100mm Aluminum Tube : 80mm Aluminum Tube
120mm Aluminum Tube : 150mm Aluminum Tube
200mm Aluminum Tube : Aluminum Tube
Kitchen Ventilator Pipe : Toilet Ventilator Pipe
exhaust fan pipe : Ventilator Tube
Double-deck Ventilator Pipe : high temperature resistance
round vent cover : wall air vent grille
ventilation duct : ventilation cover
ventilation pipe : ventilation system
valve for ventilation : for kitchen
Installation and Replacement Instructions
Stretching and Bending Requirements: During installation, fully stretch and unfold the pipe body. If turning is required, the bending radius should not be too small (it is recommended to be no less than twice the pipe diameter) to avoid flattening of the pipe body, which may increase the exhaust resistance.
Interface sealing treatment: At the connection points, it is recommended to use heat-resistant aluminum foil tape for wrapping and sealing, and then fix it with clamps or ties to ensure the interface is firmly sealed without any air leakage.
Fixed support: If the pipeline is long, hangers or supports should be installed for fixation to prevent excessive sagging which may affect the smoke exhaust efficiency. The sagging amount between two fixation points should not exceed 50mm per meter.