2P 3P 4P 40KA T2 DC SPD House Surge Protector Protective Low-Voltage Arrester Device 500V 600V 1000V 275V 385V(2,600VDC) in Saudi Arabia 2P 3P 4P 40KA T2 DC SPD House Surge Protector Protective Low-Voltage Arrester Device 500V 600V 1000V 275V 385V(2,600VDC) in Saudi Arabia 2P 3P 4P 40KA T2 DC SPD House Surge Protector Protective Low-Voltage Arrester Device 500V 600V 1000V 275V 385V(2,600VDC) in Saudi Arabia 2P 3P 4P 40KA T2 DC SPD House Surge Protector Protective Low-Voltage Arrester Device 500V 600V 1000V 275V 385V(2,600VDC) in Saudi Arabia 2P 3P 4P 40KA T2 DC SPD House Surge Protector Protective Low-Voltage Arrester Device 500V 600V 1000V 275V 385V(2,600VDC) in Saudi Arabia

2P 3P 4P 40KA T2 DC SPD House Surge Protector Protective Low-Voltage Arrester Device 500V 600V 1000V 275V 385V(2,600VDC)

SAR 435

1 +

Special Features

  • Gas Tube Arrestors

Description

Gas Tube Arrestors
SPD Type
Type 2
Technology
MOV (Metal Oxide Varistors)
Max. continuous operating voltage [Ucpv]
500Vdc/600Vdc/800Vdc/1000Vdc/1200Vdc
Nominal discharge curent(8/20us) [ln]
20kA
Max.discharge current (8/20us) [lmax]
40KA
Voltage Protection level [Up]
2.2kV
Short-circuit current rating [Isccr]
25kA
Response time [tA]
25ns
Thermal Disconnection Device
Insertion
Max. Backup Fuse
63A gPV FUSE
Mechanical Data
SPD configuration
DC system
Plugable
Available
Mounting
35mm DIN rail
Enclosure Material
Thermoplastic,conform to UL94 V-0
0perating Temperature Range
-40°C...-80°C
Protection rating
IP20
Normal/fault Display
Green / Red
Remote Signal
Optional
Wiring for remote signaling
Max.1.5mm solid/flexible
Max.Voltage / Current for remote signaling
250V/0.1A;125V/0.2A;75V/0.5A
==========
High-concerned chemical : None
Type : Earth Leakage
Type : Circuit breaker
Model Number : SPE-40
Is Smart Device : No
Rated Voltage : 220/380V
SPD Type : Type 2
Technology : MOV (Metal Oxide Varistors)
Max. continuous operating voltage [Ucpv] : 500Vdc/600Vdc/800Vdc/1000Vdc/1200Vdc
Nominal discharge curent(8/20us) [ln] : 20kA
Max.discharge current (8/20us) [lmax] : 40KA
Voltage Protection level [Up] : 2.2kV
Short-circuit current rating [Isccr] : 25kA
Response time [tA] : 25ns
Thermal Disconnection Device : Insertion
Max. Backup Fuse : 63A gPV FUSE
SPD configuration : DC system
Mounting : 35mm DIN rail
Enclosure Material : Thermoplastic,conform to UL94 V-0
Operating Temperature Range : -40°C-80°C
Protection rating : IP20
Normal/fault Display : Green / Red
Remote Signal : Optional
Wiring for remote signaling : Max.1.5mm solid/flexible
Max.Voltage / Current for remote signaling : 250V/0.1A;125V/0.2A;75V/0.5A